Johnson Spring Auditorium
Ridgecrest’s Flagship Meeting Facility — Johnson Spring

Ballroom: 500 capacity
Boardroom: 1 room, seating for 12
Classrooms: 5 to 23 rooms based on desired partition usage
Located in the heart of Ridgecrest Conference Center, Johnson Spring is our flagship meeting facility, providing various meeting options for your large or small group. This 46,250 square foot state-of-the-art facility gives meeting planners the utmost flexibility to ensure a successful meeting, convention, or retreat. Johnson Spring connects our campus with covered walkways and elevators for easy access between sleeping rooms, meeting rooms and the dining room.
Johnson Spring 2 A-C
Sound System
Mixer:
Midas M32
Outputs:
Mix LR: Main LR Outputs
Bus 1-5 – FOH Monitoring Sends
Bus 13-16 – FX
M/C – Subs
Stage Monitors:
Wedges Available Upon Request
(5) Monitor Mixes Total
(3) Sennheiser ew 300 IEM G3 Systems
We have two monitor channels and three In-ear monitors that can be simultaneously used
Speakers:
Main Fills: LR (4) EAW NT29
Sub Woofers: (2) EAW NT22
Processing Gear:
Floor Position: Digital signal processing is supplied via the Midas M32.
Input Devices:
(4) Shure ULX Series Wireless Handhelds
(2) Shure ULX Series Wireless Body Packs
Wired Microphones: Other types are available upon request.
Johnson Spring 2 A-C has a total of 16 inputs supplied via the Behringer S16 digital stage box at the stage. Local inputs are supplied at Front of House.
Lighting System
Console:
LSC Stage Setter 8 Channel with DMX Wireless Transmitter
Non-moving Fixtures:
(3) ETC Source Four Pars
(3) Rockville ROCKPar 50
(4) Amercian DJ MEGA Par Profile
Dimmers:
(1) Leprecon ULD-360-HP with Wireless DMX Receiver
Lighting System Technical Notes:
Our lighting fixtures are set up so that we may effectively serve all events we host. As such, we do not offer an option to move these fixtures.
Video Systems
Projection/Screen:
DVS Optic-3X LED wall with a resolution of 1880×600
Switching Gear:
(1) Kramer VP-734 Scaler/Switcher
Emergency Situations
In case of power failure, an emergency generator will power a few emergency auditorium lights, exit lights and stairwell lights only. The generator does not supply electricity to the sound and stage lighting. North Carolina State law requires Event Planners to notify event attendees of the location of emergency exits in their meeting space.
Johnson Spring 2 A-C Statistics
Interior Dimensions (rear wall to backstage wall x sidewall to sidewall) — 120’ x 68’
Ceiling Height (from main floor – average) — 12’
Seating Capacity (depends on room set-up) — 400 – 600
Stage Area
Height of Stage from Main Floor — 2’
Stage Ceiling Height — 10’
Video Projection Screen Size (2) — 9’ H x 12’ W
Portable Staging (9 pieces) — 12’ x 24’
Johnson Spring Technical Form
This completed form must be returned to your Event Coordinator at least two weeks prior to your event in order for our team to fulfill the needs of your event.
Video
Johnson Spring Program Office
Johnson Spring Classroom
Isaiah 64:3

Let’s Get Started!
Connect with our sales team to create your Christian meeting, conference or event. Request a proposal to get started.